7.5 hp VFD, Single Phase to Three Phase VFD
7.5 hp variable frequency drive, single phase to three phase VFD, 24 amps, RS485 enabled, manufacturer direct sale.
SKU: GK3000-2S0055G
Single phase 7.5 hp VFD, single phase 220V to three phase variable frequency drive, 24 amps. Using it as a phase converter to convert 1-phase 220v (230v, 240v) home power supply to drive 3-phase motors.
Other types of VFDs provide you with more possibilities plus the same highly-efficient and stable performance. They are 2hp, 5hp, 10hp, 15hp & 20hp.
Product Parameters
Basics | Model | GK3000-2S0055G |
Capacity | 7.5 hp (5.5 kW) | |
Shipping weight | 11 kg | |
Dimension | 339*231*234 mm | |
I/O Feature | Rated current | 24 A |
Input voltage | 1 phase 220~240V AC | |
Input frequency | 50Hz/ 60Hz | |
Output voltage | 3 phase AC 0~input voltage | |
Output frequency | 0.00~400.00Hz | |
Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
Control Feature | Control mode | V/F control; Sensorless vector control; |
Communication | RS485 | |
Speed regulation | 1:100 | |
Start torque | 150% of rating torque at 1 Hz | |
Speed control accuracy | ≤±0.5% of rating synchronous speed | |
Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
Interior PID controller | Be convenient to make closed-loop system | |
Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
Environment | Enclosure rating | IP 20 |
Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
Humidity | 5%-95%, without condensation | |
Altitude | ≤1000m; VFD will be derated if above 1000m | |
Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: Difference between VSD, VFD, ASD, AFD
The most correct term – according to IEEE and IEC – is ASD (Adjustable Speed Drive). This refers to the electronic equipment used to regulate the operating speed of the motor and driven equipment by controlling the frequency and voltage applied to the motor.
NOTE that other terms in common use include (but are not limited to): VSD (Variable Speed Drive), AFD (Adjustable Frequency Drive), and VFD (Variable Frequency Drive), they are referring to the same motor drives, just different names.
There is no difference between a VSD and VFD in terms of what it is designed to do. There MAY be differences based on specific internal components/construction and how it achieves that goal.