2 hp Single Phase to Three Phase VFD
2 hp VFD, convert single phase to three phase for AC motor speed controls, 7.5 amps, IP20, RS485 enabled.
SKU: GK3000-2S0015
Product Parameters
Basics | Model | GK3000-2S0015 |
Capacity | 2 hp (1.5 kW) | |
Shipping weight | 2 kg | |
Dimension | 142*85*113 mm | |
I/O Feature | Rated current | 7.5 A |
Input voltage | 1 phase 220~240V AC | |
Input frequency | 50Hz/ 60Hz | |
Output voltage | 3 phase AC 0~input voltage | |
Output frequency | 0.00~400.00Hz | |
Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
Control Feature | Control mode | V/F control; Sensorless vector control; |
Communication | RS485 | |
Speed regulation | 1:100 | |
Start torque | 150% of rating torque at 1 Hz | |
Speed control accuracy | ≤±0.5% of rating synchronous speed | |
Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
Interior PID controller | Be convenient to make closed-loop system | |
Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
Environment | Enclosure rating | IP 20 |
Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
Humidity | 5%-95%, without condensation | |
Altitude | ≤1000m; VFD will be derated if above 1000m | |
Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: Variable Frequency Drive Wiring Specification Standard
Signal line and power line must be separated: When using analog signals for remote control of the VFD, in order to reduce interference, the signal line and strong circuit (main circuit and sequential circuit) should be separated, and the distance should be above 30cm. Even in the control cabinet, the wiring specification should be maintained. The maximum length of the control circuit between the signal and the VFD should not exceed 50m.
Signal lines and power lines must be placed in different metal conduits or metal hose: If the PLC and the VFD signal line are not placed in metal conduit, it will be easily affected by the external interference and VFD. For there is no built-in reactor, the VFD input and output power line will have a strong interference on the outside, so the metal conduit or metal hose must be extended to the VFD control terminal to ensure that the signal line thoroughly separate from the power line.
- Analog control signal line should be used double stranded shielded wire, wire size 0.75mm2. In the wiring must note that the cable stripping should be as short as possible (5-7mm). The stripped shield layer should be wrapped with insulating tape to prevent introduce interference from shielded cable and other equipment.
- In order to improve the wiring simplicity and reliability, the signal line using pressure wire rod terminal is recommended.